Home


Product Catalog


Design


About our company


Contact Us

TSLe
SELF-REGULATING HEATER CABLE

  1. 16 AWG Buss Wires
  2. Conductive Core
  3. Polyolefin Jacket
  4. Tinned Copper Braid
  5. Standard Overjacket

 

TSLe is a light duty industrial/commercial grade self-regulating heater cable that can be used for freeze protection in various applications.

TSLe is approved for use in hazardous and certain corrosive envrionments and has multinational approvals. The heater cable can maintain temperatures up to 149°F and have an intermittent exposure temperature of 185°F when de-energized. The standard TPE overjacket provides corrosion resistance against certain inorganic chemicals and the fluoropolymer overjacket protects the cable from abrasion and impact damage while resisting organic chemicals.

TSLe self-regulating heater cables can be cut to length in the field using standard electrical tools and will not overheat or burnout when overlapped.

TSle self-regulating heating cables provide freeze protection and process temperature maintenace for fluid transport and storage systems.

AVAILABLE CONFIGURATIONS

  • CR - TPE overjacket
  • CT - Fluoropolymer overjacket

 

Factory Mutual:
Ordinary Locations
Hazardous Locations

Class 1 Div. 2, Groups B,C,D
Class 2 Div. 2, Groups F,G
Class 3 Div. 2

CSA:
Ordinary Locations, 3(A,B,C), 5(A,B)
Hazardous Locations

Class 1 Div. 2, Groups A,B,C,D
Class 2 Div. 2, Groups F,G
Class 3 Div. 2

 

Typical Heaters
208 VAC
220 VAC
240 VAC
277 VAC
TSLe 3-2
3.14
3.43
3.87
4.75
TSLe 5-2
4.50
4.87
5.50
6.58
TSLe 7-2
6.31
6.65
7.36
8.55
TSLe 9-2
8.78
9.15
9.72
10.8
PL-1
Power Connection Kit
EC-1
End Termination Kit
ESK-1
Inline Splice Kit
TSK-1
Tee Splice Kit
AL-1
Aluminum Tape
FG-1
Fiberglass Tape
TAD-1
Snap Action Thermostat
T-115
Ambient Sensing Thermostat
T-119
Line Sensing Thermostat
Sample Heaters
40°F Start-Up (Ft.)
0°F Start-Up (Ft.)
-40°F Start-Up (Ft.)

6A

10A

16A

20A

6A

10A

16A

20A

6A

10A
16A
20A
TSLe 3-1
TSLe 3-2

256

433

590

183
308
492

150
250
407

505

TSLe 5-1
TSLe 5-2

203

340

479

157
270
426
479
138
230
367
452
TSLe 7-1
TSLe 7-2

151

250

406

112
183
288
360
92
150
236
295
TSLe 9-1
TSLe 9-2
112
190
300

335

78
131
184
216
65
111
177
216

 

[Download PDF]

Note: For heater cable applications refer to: National Electric Code, Article 427; Fixed electric heating for pipelines and vessels.
 